Group3 Digital Hall Effect Teslameter

The DTM-151 Digital Teslameter offers extremely accurate, high resolution measurement of magnetic flux densities.

 

Accuracy is 0.01% of reading + 0.006% of full scale when used with the LPT-141 or MPT-141 probe.

Features:

- High accuracy - fully temperature compensated

- Resolution of 1 part in 600,000

- 4 ranges

- Maximum field - 3 Tesla

- 7 Digit display

- Either RS232 or IEEE488/GPIB communications

 

DTM-151 performance summary when combined with the listed probe

Probe
Active Area (mm)
Resolution of Display
Max Field
Finest Resolution
Accuracy at 25°C
Tempco ppm/°C

Zero Drift µT/°C
LPT-141
4 x 1.6
1 in 600,000
3T
1µT
±0.01% 
±10
±1
LPT-231
4 x 1.6
1 in 600,000
0.3T
0.1µT
±0.03%
±25
±1
MPT-141
1 x 0.5
1 in 600,000
3T
1µT
±0.01%
±10
±1
MPT-231
1 x 0.5
1 in 600,000
0.3T
0.1µT
±0.03%
±25
±1

 

 

The DTM-150 Digital Teslameter offers all the features of the DTM-151, however the accuracy is 0.03% of reading +0.006% of full scale when used with the LPT-130 or MPT-132 probe.

 

DTM-150 performance summary when combined with the listed probe

Probe
Active Area (mm)
Resolution of Display
Max Field
Finest Resolution
Accuracy at 25°C
Tempco ppm/°C

Zero Drift µT/°C
LPT-130
4 x 1.6
1 in 600,000
3T
1µT
±0.03% 
-80
±12
LPT-230
4 x 1.6
1 in 600,000
0.3T
0.1µT
±0.03%
-620
±12
MPT-132
1 x 0.5
1 in 600,000
3T
1µT
±0.03%
-140
±40
MPT-230
1 x 0.5
1 in 600,000
0.3T
0.1µT
±0.03%
-800
±12

 

 

The DTM-133 Digital Teslameter offers the following features:

- Resolution of 1 part in 12,000

- 4 ranges

- Maximum field 3 Tesla

- 6 Digit display (5 digit, plus sign)

- Optional RS232 or IEEE488/GPIB communications

Accuracy is ±(0.03% of reading + 0.03% of full scale) when used with the LPT-130 or MPT-132 probe.

Temperature coefficient is -80ppm/°C max when used with LPT-130 or

-140 ppm/°C max when used with MPT-132 probe.

Accuracy and temperature specifications include the performance of the probe

 

DTM-133 performance summary when combined with the listed probe

Probe
Active Area (mm)
Resolution of Display
Max Field
Finest Resolution
Accuracy at 25°C
Tempco ppm/°C

Zero Drift µT/°C
LPT-130
4 x 1.6
1 in 12,000
3T
50µT
±0.03% 
-80
±12
LPT-230
4 x 1.6
1 in 12,000
0.3T
5µT
±0.03%
-620
±12
MPT-132
1 x 0.5
12,000
3T
1µT
±0.03%
-140
±40
MPT-230
1 x 0.5
1 in 600,000
0.3T
0.1µT
±0.03%
-800
±12