| Prodyn Standard Current Probes and I-Dot Sensors
The Kwik Latch® and spring clamp-on models are self-integrating sensors which are hinged and therefore clamp on to a conductor to be tested, without having to pass them through the sensor aperture. Other models, with fixed apertures, are used to measure current on wire where the best high frequency characteristics are desired.
PRODYN is one of the only companies that manufacture I-Dot type sensors. These differentiating type sensors, which measure the first time derivative of the total current through the aperture, have unique characteristics that enable the user to measure higher frequencies and have better current handling capability than self-integrating sensors. They are also available in the Kwik Latch® hinged design to allow for clamp-on requirements.
| Model |
Frequency Range |
Zt Ω |
Maximum Output Voltage (Vo) |
Average Current Max (CW)A |
Peak Current Max - A |
Pulse
Width
ζmax - μS |
Rep Rate KHz |
| I-075-1B |
70KHz-130MHz* |
5 |
2,000 |
35.10 |
360 |
.22 |
3995.00 |
| I-125-1A |
10KHz-100MHz |
5 |
2,000 |
39.30 |
320 |
2.059 |
478.00 |
| I-125-1B |
90KHz-110MHz* |
5 |
2,000 |
35.10 |
360 |
.368 |
2389.00 |
| I-125-1D |
25KHz-80MHz* |
5 |
2,000 |
27.80 |
360 |
1.000 |
696.87 |
|
| I-125-1HF |
120KHz-600MHz* |
5 |
400 |
1.29 |
76 |
.392 |
.734 |
| I-125-2A |
10KHz-150MHz |
1 |
400 |
4.26 |
456 |
9.010 |
.0097 |
| I-125-2C |
50KHz-5MHz* |
1 |
2,000 |
145.00 |
1,880 |
5.222 |
697.00 |
| I-125-2HF |
80KHz->500MHz* |
1 |
400 |
4.42 |
400 |
1.306 |
.191 |
| I-125-3A |
10KHz-100MHz |
.03 |
400 |
23.20 |
13,397 |
10.297 |
.00029 |
| I-125-4A |
10KHz-100MHz |
.1 |
400 |
12.80 |
4,064 |
10.297 |
.000009 |
| I-125-6 |
60Hz-10MHz |
.5 |
400 |
258.00 |
4,200 |
6.117 |
1,054.512 |
| I-125-7 |
540Hz-30MHz |
1 |
2,000 |
11.30 |
389 |
15.554 |
.00055 |
| I-125-9A |
10KHz-200MHz |
.005 |
400 |
60.00 |
80,072 |
4.999 |
.000001 |
| I-262-2A |
10KHz-50MHz |
5 |
400 |
99.60 |
320 |
4.597 |
542.00 |
| I-262-3A |
10KHz-140MHz |
2 |
2,000 |
2.32 |
232 |
11.492 |
.0087 |
| I-262-4A |
10KHz-100MHz |
.06 |
400 |
12.90 |
6,707 |
14.365 |
.00026 |
| I-262-5A |
10KHz-200MHz |
.1 |
400 |
2.59 |
424 |
8.619 |
.0044 |
| I-262-6A |
5KHz-160MHz* |
.1 |
400 |
9.01 |
4,032 |
11.49 |
.000011 |
| I-300A |
180KHz-300MHz* |
5 |
1,500 |
30.90 |
400 |
.022 |
35,555.92 |
| I-310A |
50KHz-200MHz* |
1 |
400 |
4.97 |
395 |
.163 |
.9721 |
| I-400A |
50KHz->450MHz* |
5 |
1,500 |
30.90 |
400 |
.136 |
5,694.008 |
| I-410A |
15KHz->450MHz* |
1 |
400 |
4.97 |
395 |
.680 |
.2335 |
| I-2400-12 |
100Hz - 2MHz |
.001 |
3,000 |
8,820.00 |
3,000,000 |
508.00 |
.000721 |
Current Probe Selection Guide
IP-2 Series High Frequency Current Sensor
IP 10 & 50 Current Probe
CIP 10 & 50 Cable Current Probe
CIP 100 & 500 Cable Current Probe
|