Group3 Digital Hall Effect Teslameter

The DTM-151 Digital Teslameter offers extremely accurate, high resolution measurement of magnetic flux densities.

 

Accuracy is 0.01% of reading + 0.006% of full scale when used with the LPT-141 or MPT-141 probe.

Features:

- High accuracy - fully temperature compensated

- Resolution of 1 part in 600,000

- 4 ranges

- Maximum field - 3 Tesla

- 7 Digit display

- Either RS232 or IEEE488/GPIB communications

 

DTM-151 performance summary when combined with the listed probe

Probe Active Area (mm) Resolution of Display Max Field Finest Resolution Accuracy at 25°C Tempco ppm/°C

Zero Drift µT/°C
LPT-141 4 x 1.6 1 in 600,000 3T 1µT ±0.01%  ±10
±1
LPT-231 4 x 1.6 1 in 600,000 0.3T 0.1µT ±0.03% ±25
±1
MPT-141 1 x 0.5 1 in 600,000 3T 1µT ±0.01% ±10
±1
MPR-231 1 x 0.5 1 in 600,000 0.3T 0.1µT ±0.03% ±25
±1

 

 

The DTM-150 Digital Teslameter offers all the features of the DTM-151, however the accuracy is 0.03% of reading +0.006% of full scale when used with the LPT-130 or MPT-132 probe.

 

DTM-150 performance summary when combined with the listed probe

Probe Active Area (mm) Resolution of Display Max Field Finest Resolution Accuracy at 25°C Tempco ppm/°C

Zero Drift µT/°C
LPT-130 4 x 1.6 1 in 600,000 3T 1µT ±0.03%  -80
±12
LPT-230 4 x 1.6 1 in 600,000 0.3T 0.1µT ±0.03% -620
±12
MPT-132 1 x 0.5 1 in 600,000 3T 1µT ±0.03% -140
±40
MPR-230 1 x 0.5 1 in 600,000 0.3T 0.1µT ±0.03% -800
±12

 

 

The DTM-133 Digital Teslameter offers the following features:

- Resolution of 1 part in 12,000

- 4 ranges

- Maximum field 3 Tesla

- 6 Digit display (5 digit, plus sign)

- Optional RS232 or IEEE488/GPIB communications

Accuracy is ±(0.03% of reading + 0.03% of full scale) when used with the LPT-130 or MPT-132 probe.

Temperature coefficient is -80ppm/°C max when used with LPT-130 or

-140 ppm/°C max when used with MPT-132 probe.

Accuracy and temperature specifications include the performance of the probe

 

DTM-133 performance summary when combined with the listed probe

Probe Active Area (mm) Resolution of Display Max Field Finest Resolution Accuracy at 25°C Tempco ppm/°C

Zero Drift µT/°C
LPT-130 4 x 1.6 1 in 12,000 3T 50µT ±0.03%  -80
±12
LPT-230 4 x 1.6 1 in 12,000 0.3T 5µT ±0.03% -620
±12
MPT-132 1 x 0.5 12,000 3T 1µT ±0.03% -140
±40
MPR-230 1 x 0.5 1 in 600,000 0.3T 0.1µT ±0.03% -800
±12