Home
Products
Markets
Support
Contact us
Sitemap
Products - Home
AC Coupled Links
DC Coupled Links
Intelligent FOL
EM Probes
Current Probes
Teslameters
Control
Tempest Receiver
EMC Receivers
HV Probes
HV Attenuators
Lab Power Supply
Data Recorders
Transient Recorder
point2point AC Coupled Analogue Fibre Optic Links

PPM’s point2point range of AC Analogue Fibre Optic Links are high performance analogue data transmission systems, which provide great benefits to users who require a solution to electrical interference and signal attenuation problems in signal monitoring and distribution over distance.

The user applies an RF signal to the input of the Optical Transmitter. The signal is amplified and conditioned, and converted into an optical signal for transmission over the optical fibre. At the Optical Receiver, the optical signal is converted back into an electrical signal. Due to the analogue nature of this technique, the link may be used to convey data of almost any format within the specified frequency limits.

The low noise figure of the point2point system allows the link to be used in DEF STAN 59-411 testing including DRE04 Electric Field Radiated Emissions Installed Antenna.  The low noise figures of the point2point links enable detection and measurement of small disturbances, even when a considerable distance is required from the DUT.

 
PAx-Gx-6x
PAx-Kx-6X
Bandwidth (-3dB)
<40Hz to >250MHz <2kHz to >1.35GHz
Jitter (measured on a 100MHz sinewave)
<10ps rms <10ps rms
Simultaneous Dynamic Range @ 100MHz
>150dB in a 1Hz bandwidth >150dB in a 1Hz bandwidth
Gain Stability
Better than ± 0.25dB after 20 minutes warm up Better than ± 0.25dB after 20 minutes warm up
Passband Flatness

40Hz - 100kHz: ± 1.5dB

100kHz - 250MHz: ±0.75dB

2kHz - 100kHz: ± 1.5dB

100kHz - 1.35GHz: ±1dB (typ 0.5dB)

Phase Flatness
>100Hz: ± 20° >5kHz: ± 20°
Input P1dB
>0dBm @ 100MHz >0dBm @ 500MHz
Input IP3
>10dBm @ 100MHz >10dBm @ 500MHz

 
PAx-Px-6x
PAx-Sx-6X
Bandwidth (-3dB)
<1MHz to >2GHz <10MHz to >3GHz
Jitter (measured on a 100MHz sinewave)
<10ps rms <10ps rms
Simultaneous Dynamic Range @ 100MHz
>150dB in a 1Hz bandwidth >150dB in a 1Hz bandwidth
Gain Stability
Better than ± 0.25dB after 20 minutes warm up Better than ± 0.25dB after 20 minutes warm up
Passband Flatness
± 1dB ± 1dB
Phase Flatness
± 20° (typ ± 5° for 1MHz to 1.5GHz) ± 20° (typ ± 5° for 1MHz to 1.5GHz)
Input P1dB
>0dBm @ 500MHz >0dBm @ 500MHz
Input IP3
>10dBm @ 100MHz >10dBm @ 500MHz

Technical Specification - point2point AC Coupled Links

Frequently asked questions about point2point modules

Key Features
  • Wide, flat frequency response for accurate transmission of broadband signals
  • Electrically screened Shielded Remote Module option for operation in high levels of electrical interference
  • A range of input and output signal levels
  • Suitable for all modulation formats
  • Wide dynamic range to permit simultaneous monitoring of low and high level signals
  • Visual indication of received optical signal level at Receiver
Key Benefits
  • Immunity to electrical interference, so the signal is not corrupted by radiated interference
  • Low loss, enabling very long path lengths with negligible degradation of signal-to-noise
  • Frequency response independent of path length
  • Non-conductive providing an intrinsically safe transmission path for the monitoring of equipment at hazardous voltages
  • Highly flexible and small diameter cable

 

If you are looking for information on Fibre Optic Links for SatCom, Broadcast, antenna remoting, military, security, GPS timing, cellular or radio applications then please visit www.vialite.co.uk for more information. sales@ppm.co.uk +44 1793 784389

©Pulse Power & Measurement Ltd. 2009